title: "Tuya PA-44Z control via MQTT"
3
description: "Integrate your Tuya PA-44Z via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway."
4
addedAt: 2023-06-01T08:16:21
5
pageClass: device-page
6
---
7

            
8
<!-- !!!! -->
9
<!-- ATTENTION: This file is auto-generated through docgen! -->
10
<!-- You can only edit the "Notes"-Section between the two comment lines "Notes BEGIN" and "Notes END". -->
11
<!-- Do not use h1 or h2 heading within "## Notes"-Section. -->
12
<!-- !!!! -->
13

            
14
# Tuya PA-44Z
15

            
16
|     |     |
17
|-----|-----|
18
| Model | PA-44Z  |
19
| Vendor  | [Tuya](/supported-devices/#v=Tuya)  |
20
| Description | Photoelectric smoke detector |
21
| Exposes | smoke, battery, silence, test, smoke_concentration, device_fault |
22
| Picture | ![Tuya PA-44Z](https://www.zigbee2mqtt.io/images/devices/PA-44Z.png) |
23

            
24

            
25
<!-- Notes BEGIN: You can edit here. Add "## Notes" headline if not already present. -->
26
## Notes
27

            
28
### Pairing
29
Press test button for 10 seconds.
30
<!-- Notes END: Do not edit below this line -->
31

            
32

            
33

            
34

            
35
## Exposes
36

            
37
### Smoke (binary)
38
Indicates whether the device detected smoke.
39
Value can be found in the published state on the `smoke` property.
40
It's not possible to read (`/get`) or write (`/set`) this value.
41
If value equals `true` smoke is ON, if `false` OFF.
42

            
43
### Battery (numeric)
44
Remaining battery in %, can take up to 24 hours before reported.
45
Value can be found in the published state on the `battery` property.
46
It's not possible to read (`/get`) or write (`/set`) this value.
47
The minimal value is `0` and the maximum value is `100`.
48
The unit of this value is `%`.
49

            
50
### Silence (binary)
51
Silence the alarm.
52
Value can be found in the published state on the `silence` property.
53
It's not possible to read (`/get`) this value.
54
To write (`/set`) a value publish a message to topic `zigbee2mqtt/FRIENDLY_NAME/set` with payload `{"silence": NEW_VALUE}`.
55
If value equals `true` silence is ON, if `false` OFF.
56

            
57
### Test (binary)
58
Indicates whether the device is being tested.
59
Value can be found in the published state on the `test` property.
60
It's not possible to read (`/get`) or write (`/set`) this value.
61
If value equals `true` test is ON, if `false` OFF.
62

            
63
### Smoke concentration (numeric)
64
Parts per million of smoke detected.
65
Value can be found in the published state on the `smoke_concentration` property.
66
It's not possible to read (`/get`) or write (`/set`) this value.
67
The unit of this value is `ppm`.
68

            
69
### Device fault (binary)
70
Indicates a fault with the device.
71
Value can be found in the published state on the `device_fault` property.
72
It's not possible to read (`/get`) or write (`/set`) this value.
73
If value equals `true` device fault is ON, if `false` OFF.
74